Complete Guide to Installing Vethy Parking Air Conditioners: Save Money and Improve Comfort
February 06, 2025
The Problem Every Truck Driver Faces
Truck drivers spend long hours on the road. During breaks, they need to rest in their cabins. But resting in a hot truck cabin is not easy. Many drivers keep the engine running to power the air conditioner. This causes three big problems:
High Fuel Costs: A truck idling for 6 hours daily burns 3.5 liters of fuel per hour. At 1.50perliter,thiswastes3,150 every year.
Engine Damage: Idling for hours wears out engine parts faster. Repair costs can reach 5,000−10,000 over 5 years.
Legal Issues: Many cities ban unnecessary idling. Fines range from 100to1,500 per violation.
A Vethy parking air conditioner solves all these problems. It cools the cabin using battery power, not the engine.
How Vethy Parking ACs Work: Simple but Effective
Most parking coolers only lower the temperature. But Vethy systems do two things better:
Cool the Air: Removes heat using compressor technology.
Remove Humidity: Pulls moisture from the air so sweat can evaporate.
Why This Matters:
At 90°F (32°C), dry air feels like 84°F (29°C) if humidity is below 50%.
At the same temperature but 70% humidity, it feels like 100°F (38°C).
Vethy units keep humidity under 60%, making 80°F (27°C) feel comfortable.
Vethy Parking AC Models: Detailed Comparison
We offer four models for different needs. Below are full technical specs:
1. Vethy VBPSO3 (Best for Small Trucks)
Specification | 12V Model | 24V Model |
---|---|---|
Cooling Capacity | 1800W | 2400W |
Power Consumption | 500-800W | 350-1000W |
Compressor Speed | 1000-2500 RPM | 1000-3000 RPM |
Refrigerant | R134a (600g) | R134a (600g) |
Noise Level | 48 dB | 50 dB |
Dimensions (LxWxH) | 400x490x330mm | 400x490x330mm |
Weight | 29 kg | 31 kg |
Key Benefits:
Fits trucks with roof heights under 10 feet.
Uses standard R134a refrigerant (easy to find).
2. Vethy V4000 (Heavy-Duty Cooling)
Specification | Details |
---|---|
Cooling Capacity | 4000W |
Voltage Options | 48V/110V/220V |
Power Consumption | 45A |
Refrigerant | R410A (900g) |
Noise Level | 55 dB |
Dimensions (LxWxH) | 862x988x190mm |
Weight | 42 kg |
Key Benefits:
Cools large sleeper cabins up to 300 sq.ft.
Built-in overload protection for hot climates.
3. Vethy VSO1 & VSO2 Pro (Quiet Operation)
Specification | VSO1 (12V/24V) | VSO2 Pro (12V/24V) |
---|---|---|
Cooling Capacity | 2200W/2800W | 2000W/2400W |
Refrigerant | R32 (650g) | R32 (650g) |
Noise Level | 45 dB | 43 dB |
Dimensions (LxWxH) | 825x980x180mm | 680x980x180mm |
Weight | 34.5 kg | 31 kg |
Key Benefits:
R32 refrigerant reduces global warming impact by 70% vs R134a.
"Eco Mode" cuts power use by 30% during nighttime.
Step-by-Step Installation Guide (With Pictures)
Tools You Need
Basic Tools:
Drill (30−50 models from DeWalt or Makita)
Screwdriver set (Phillips and flathead)
Wire strippers (10-18 AWG capacity)
Multimeter (20−40 models from AstroAI)
Special Tools:
Vacuum pump (150−300 models like Robinair 15500)
Flaring tool kit (50−80 for copper pipes)
Manifold gauge set (80−120 for refrigerant checks)
Materials:
Insulation foam tape (1/2” thickness)
6mm² or 10mm² copper wire (length depends on truck size)
Drain hose (1/2” diameter PVC)
Installation Process
Step 1: Mount the Indoor Unit
Choose Location:
For roof-mounted units (VBPSOB/VSO1), measure 16” from the front edge.
For wall-mounted units (V4000), center it on the rear cabin wall.
Cut the Hole:
Use a hole saw bit matching the unit’s size (e.g., 14” for VSO1).
Sand edges to prevent metal cracks.
Secure the Unit:
Apply butyl tape around the hole for waterproofing.
Bolt the unit down with M8 stainless steel screws.
Step 2: Connect Refrigerant Pipes
Bend Copper Pipes:
Use a pipe bender tool. Never bend by hand—it causes kinks.
Minimum bend radius: 4x pipe diameter (e.g., 1/4” pipe needs 1” radius).
Flare Pipe Ends:
Cut pipes to length with a tube cutter.
Make 45-degree flares using the flaring tool.
Vacuum the System:
Connect gauges to service ports.
Run the vacuum pump for 20 minutes to remove moisture.
Step 3: Wire the Electrical System
Connect to Batteries:
For 12V systems: Use 6mm² wire if the cable run is under 10 feet.
For 24V systems: 4mm² wire works for runs up to 15 feet.
Add a Fuse:
Install a 50A fuse within 12” of the battery.
Use waterproof fuse holders in humid areas.
Test the System:
Turn on the AC and check voltage drop with a multimeter.
If voltage drops over 0.5V, upgrade to thicker wires.
Real-World Test Results
We tested Vethy ACs in Arizona summer heat (115°F/46°C):
Model | Time to Cool 80°F | Power Use | Noise Level |
---|---|---|---|
VBPSOB (24V) | 22 minutes | 900W | 50 dB |
V4000 | 18 minutes | 1200W | 55 dB |
VSO2 Pro | 25 minutes | 700W | 43 dB |
Key Findings:
V4000 cools fastest but uses more power.
VSO2 Pro is best for drivers who prioritize quiet operation.
Maintenance Checklist
Follow this schedule to keep your AC running 10+ years:
Daily:
Wipe dust off vents with a microfiber cloth.
Monthly:
Wash air filters in soapy water. Let dry 24 hours before reusing.
Every 6 Months:
Check drain hoses for clogs. Use a wet/dry vacuum to clear debris.
Every 2 Years:
Recharge refrigerant if cooling slows down.
Tighten all electrical connections.
Troubleshooting Common Issues
Problem: AC blows warm air.
Solution:
Check refrigerant pressure (should be 60-80 PSI on low side).
Look for oil stains around pipes—this indicates leaks.
Problem: Water leaks inside cabin.
Solution:
Ensure drain hose slopes downward 1/4” per foot.
Pour 1 cup of vinegar through the drain to clear algae.
Problem: Fuse keeps blowing.
Solution:
Replace 50A fuse with a 60A fuse if using long wire runs.
Clean battery terminals to reduce resistance.
Where to Buy and Get Support
Online:
Amazon: Search “Vethy VBPSOB” or “Vethy V4000”.
eBay: Look for certified sellers with 98%+ positive feedback.
Local Stores:
Find dealers in your area using our Store Locator.
Customer Service:
Call +1-800-555-1234 for installation help.
Email kevin@vethy.com for wiring diagrams.